hohner

    Hohner Automation Ltd.


Home Email About Us Products Barriers Distributors Custom News

INC-00X Inclinometer and Accelerometer (Cerberus)

(combination inclinometer + accelerometer available)


M   X K 0 - 3 X X X - X X X X
 

|

 

Shaft

 

Output

  |  

|

    

Inclination Angle

| |

|

| | Inclination
| | 36 = 4...20mA | | 0015 = +/-15 deg
  |   |

37 = Voltage

|  

|

0030 = +/-30 deg
|

|

| | up to +/- 90deg
| Shaft Size |

|

Acceleration

| K0 = Inclinometer | | 0002 = +/-2g
| KK = Accelerometer

|

| 0004 = +/-4g
| KC = Inclin + Accel | | up to +/-16g

|

|

|

Protection | Orientation (see below)
E = IP66/67 Stainless Steel | A = Angle 'b'

 with 4x M5 on 2.92" PCD

| R = Angle 'c'
H = IP66/67 Stainless Steel | B = Angle 'b' and 'c'
 with 4x 1/4-20 on 2.75" PCD | T = Triaxial
|
Connection
1 = 2m cable
3 = 10m cable

Class I, Zone 1; Zone 21; Class II, Div 2


Technical Data Connection Details
Operating temp: - 40 ...+   60 degrees C Cable
- 40 ...+ 140 degrees F Ground (0V) Black
Vibration: 5g (500 Hz) Excitation (+18-36V) Red
Shock: 10g (6msec) Angle 'a' Green
Power supply: Variable Angle 'b' Purple
Weight: 2.5Kg Angle 'c' Brown
Protection: IP 66/67 G axis 1 White
Housing: Stainless Steel G axis 2 Blue
Humidity: Up to 98% permissible G axis 3 Yellow
 
Inclinometer Details Accelerometer Details
Precision: 0.1 degrees Sensitivity: 8ma/g range
Setting time: 0.1 second Frequency Response: 0 to 100 Hz
Power Supply: 24V Non Linearity: +/- 1%
Output Current: 4...20mA Transverse Sensitivity: <=10%
Measuring Rate: 1 kHz Setting time: <= 80ms
Stability: +/-90 x 10-6/Co Power Supply: 24V
Setting time: <=80ms Output Current: 4 to 20mA
Outputs
4...20mA: + XXo / +G = 4mA and -XXo / -G = 20mA
0...10V: + XXo / +G = 0V and -XXo / -G = 10V

Certifications
Does not require a barrier for use in hazardous areas, it is Flameproof, making the barrier redundant.
IP 66/X7
Ex d IIC
ATEX [Certificate]
IECEx [Certificate]
CSA [Certificate]
GOST-CU [Certificate]
 

Mounting Instructions

Hook up the inclinometer with the connections as described.  Make sure power supply meets specifications.  Attach unit to machine or device and use the arrows indicating inclination as reference as to which axis the measurements take place.

 

Dimensions


Hohner Corp. Tel:  1 905 563 4924 and 1 800 295 5693
5536 Regional Road 81 Fax: 1 905 563 7209
Beamsville, Ontario, L0R 1B3, Canada E-mail: hohner@hohner.com

Hohner Automation Ltd. Tel: +44 (0) 1978 363-888 and 0 845 658 2020
Units 14-16, Whitegate Industrial Estate Fax: +44 (0) 1978 364-586
Wrexham, North Wales, LL13 8UG, UK E-mail: uksales@hohner.com